Skip to content
AccessibilityCustomer Service
Need help?

RELIABILT

36-in x 80-in x 4-9/16-in Steel Right-hand inswing Prehung Residential Insulating core Front Door

$359.99/ unit$558.00

SKU: 10124820

$359.99per item

Subtotal$359.99

Current stock at Marietta

Store pickup

NO STOCK AVAILABLE

Check another store or ask us about availability.

Norcross: 9 units available

Fulfillment
In-store pickup only
Check other stores & update ZIP
  • Marietta

    NO STOCK AVAILABLE

    119 Cobb Parkway North, Suite D, Marietta, Georgia 30062

    MY STORE
  • Norcross

    9 units available

    6755 Jimmy Carter Blvd, Norcross, Georgia 30071

Checking your Project List…

Adding an item does not reserve stock.

Questions about this item?

Call Marietta · (770) 874-2254Call Norcross · (770) 758-3223Ask about this item

Ask us to confirm this item’s condition and pickup availability. Item reference: 10124820. Purchases are completed in store. In-store pickup only.

Specifications

Product Information

Material
Steel

Verified model details

Reference rough opening
38-1/4 x 82 inches
Reference framed assembly
37-1/2 x 81-1/2 inches
Reference jamb size
4-9/16 inches
Reference handing
Right-hand inswing; exterior view

Product details

RELIABILT Camelia model 10124820 combines a steel front door with an insulating core and an oval decorative-glass centerpiece. The standard reference configuration is prehung, primed for painting and prepared for a lockset and deadbolt. The decorative glass distinguishes this model when comparing doors that share the same general width, height and handing.

The 36-by-80-inch designation is the common door size, not the complete framed unit or the required hole in the wall. The exact-model retailer specification lists a 37.5-by-81.5-inch assembly, a 4-9/16-inch jamb and a 38-1/4-by-82-inch rough opening. It is right-hand inswing: viewed from outside, the hinges are on the right and the door opens into the home. Confirm these reference dimensions against the available unit and your entrance.

Buying guide

Check the opening and wall depth

Record the rough opening and the wall build-up before selecting a prehung door. Compare them with the reference opening and jamb size separately; matching the common slab size is not enough. If replacing an existing entrance, inspect what remains after the old unit is removed and have the installer determine the complete frame, sill and trim arrangement. Do not assume the current visible opening describes the underlying rough opening.

Draw the swing from outside

Stand on the exterior side and mark the hinge side on a simple sketch. Draw the panel opening inward, then check the space around nearby walls, furniture and another door. Handing and swing direction are separate checks, and this configuration should not be treated as automatically reversible. Bring the sketch and opening measurements when confirming the exact model.

Compare the Camelia glass

The oval glass is the main visual distinction of this Camelia door. Compare its proportions with the entrance surround, exterior lights and other glazing on the front of the home. Look at the actual item photos and the unit itself to decide whether that decorative pattern suits your project. A similar steel door with another glass name is not an identical design.

Plan the finish and hardware

The reference door is primed for your paint choice and has two bores for a lockset and deadbolt. Select hardware from the measured preparation and the hardware manufacturer's requirements, not from the door style alone. The standard reference configuration does not supply a handle or locking system. Confirm the components with the actual AHL unit before building the final materials list.

Worked frame and opening comparison

For Camelia's reference assembly, 38.25 inches of rough-opening width minus 37.5 inches of assembly width gives 0.75 inch of total difference. The height comparison, 82 minus 81.5, gives half an inch. Those totals describe two different rectangles; they do not prescribe shim thickness, sealant space or the position of the sill. An existing 36-by-80 panel label supplies neither comparison.

Put the measured site opening, checked framed unit and reference opening together on the worksheet, then let the installer resolve the full fitting detail. This prevents a common-size match from being mistaken for an assembly-fit check.

Take a hardware-preparation record

Before choosing a lockset, record the actual bore diameters, the distance from the door edge to each bore center, the spacing between the bores and the panel thickness. Check the edge preparation and the intended latch and strike arrangement too. Compare those measurements with the selected hardware's requirements instead of assuming that two bores make every lockset compatible.

Keep a photograph with the measurements so the two sides of the primed steel door and the intended handle orientation are clear. This is a selection worksheet, not a claim about undocumented bore dimensions.

Installation & care

Review the prehung unit before installation

Inspect the panel, frame, sill, glass and visible hardware, and compare the unit's label with the model you selected. Check included components and resolve any condition concern before the installer fits the assembly. The original retailer's configuration describes the model as supplied there; it does not establish the completeness or condition of every liquidation item.

Follow the applicable fitting instructions

Have the installer use the instructions for the exact unit when preparing the opening, managing water, setting the sill and fastening the frame. The reference measurements help with selection but are not a complete installation procedure. Confirm any local requirement for the proposed entrance before relying on a door-category description.

Choose finishing and care together

Check the current finishing instructions before selecting paint, preparing the primed surface or painting around the glass and weatherstripping. Use care products appropriate for the finished door, decorative glass and hardware. Keep the model information and chosen paint details for later touch-ups; do not treat the factory primer as the final decorative finish.

Product FAQs

Will a 36-by-80-inch opening fit this prehung door?

That is the common door size, not the reference rough opening. Compare the framed assembly and required opening with the measurements at your entrance before selecting it.

How do I identify right-hand inswing?

Use the outside view: the reference unit's hinges are on the right, and the panel opens into the home. Check both parts of that description on your entrance sketch.

Is a lockset included?

The standard reference configuration is prepared for a lockset and deadbolt but does not supply a handle or locking system. Check the actual available unit and select compatible hardware separately.

Can it be used wherever a steel door is required?

Steel is a material description. It does not establish a fire rating, impact approval or compliance for every location. Have the exact proposed application checked before choosing the unit.

Does the oval glass design establish a privacy level?

The Camelia name and oval outline identify the design, but this evidence does not establish a numerical privacy rating. Inspect the actual glazing from the positions that matter at your entrance, including the view from inside and outside. Decide the appearance and visibility you want from that review rather than treating a reference photograph as a privacy test.